Skip to content

Auto Function Profile#

The Auto Function Profile camera feature allows you to specify how gain and exposure time are balanced when the camera is making automatic adjustments.

Using the Feature#

Setting the Auto Function Profile#

To set the auto function profile:

  1. Set the Gain Auto auto function and the Exposure Auto auto function to Continuous.
  2. Set the AutoFunctionProfile parameter to one of the following values (if available):

Available Auto Function Profiles#

Minimize Gain (= Gain Minimum)#

The gain is kept as low as possible during the automatic adjustment process. If the exposure time is at its upper limit and the target brightness value has not been reached yet, the gain will be increased in order to reach the target.

Minimize Exposure Time (= Exposure Minimum)#

The exposure time is kept as low as possible during the automatic adjustment process. If the gain is at its upper limit and the target brightness value has not been reached yet, the exposure time will be increased in order to reach the target.

Minimize Gain Quick (= Gain Minimum Quick)#

This profile works the same as the Minimize Gain profile. The difference is that it reacts more quickly in situations with extreme changes in brightness or where the image brightness changes rapidly. This situation occurs, for example, when microscope objective lenses are changed using the objective turret.

Minimize Exposure Time Quick (= Exposure Minimum Quick)#

This profile works the same as the Minimize Exposure Time profile. The difference is that it reacts more quickly in situations with extreme changes in brightness or where the image brightness changes rapidly. This situation occurs, for example, when microscope objective lenses are changed using the objective turret.

Smart#

Gain is kept as low as possible and the frame rate will be kept as high as possible during automatic adjustments.

This is a four-step process:

  1. The camera adjusts the exposure time to achieve the target brightness value.
  2. If the exposure time must be increased to achieve the target brightness value, the camera does so until the frame rate drops.
  3. If the frame rate drops, the camera stops increasing the exposure time and increases the gain until the AutoGainRawUpperLimit value is reached.
  4. When the AutoGainRawUpperLimit value has been reached, the camera stops increasing the gain and increases the exposure time until the target brightness value is reached. Increasing the exposure time results in a lower frame rate.

Anti-Flicker 50 Hz / 60 Hz#

Gain and exposure time are optimized to reduce flickering. If the camera is operating in an environment where the lighting flickers at a 50-Hz or a 60-Hz rate, the flickering lights can cause significant changes in brightness from image to image. Enabling the anti-flicker profile may reduce the effect of the flickering in the captured images.

Choose the frequency (50 Hz or 60 Hz) according your local power line frequency (e.g., North America: 60 Hz, Europe: 50 Hz).

Specifics#

Show all camera models

Camera Model Available Auto Function Profiles
a2A640-240gmSWIR Minimize Gain
Minimize Exposure Time
a2A640-240umSWIR Minimize Gain
Minimize Exposure Time
a2A1280-80gmSWIR Minimize Gain
Minimize Exposure Time
a2A1280-125umSWIR Minimize Gain
Minimize Exposure Time
a2A1920-51gcBAS Minimize Gain
Minimize Exposure Time
a2A1920-51gcPRO Minimize Gain
Minimize Exposure Time
a2A1920-51gmBAS Minimize Gain
Minimize Exposure Time
a2A1920-51gmPRO Minimize Gain
Minimize Exposure Time
a2A1920-160ucBAS Minimize Gain
Minimize Exposure Time
a2A1920-160ucPRO Minimize Gain
Minimize Exposure Time
a2A1920-160umBAS Minimize Gain
Minimize Exposure Time
a2A1920-160umPRO Minimize Gain
Minimize Exposure Time
a2A1920-165g5cBAS Minimize Gain
Minimize Exposure Time
a2A1920-165g5mBAS Minimize Gain
Minimize Exposure Time
a2A2048-35gmSWIR Minimize Gain
Minimize Exposure Time
a2A2048-110umSWIR Minimize Gain
Minimize Exposure Time
a2A2440-98g5cBAS Minimize Gain
Minimize Exposure Time
a2A2440-98g5mBAS Minimize Gain
Minimize Exposure Time
a2A2448-23gcBAS Minimize Gain
Minimize Exposure Time
a2A2448-23gcPRO Minimize Gain
Minimize Exposure Time
a2A2448-23gmBAS Minimize Gain
Minimize Exposure Time
a2A2448-23gmPRO Minimize Gain
Minimize Exposure Time
a2A2448-75ucBAS Minimize Gain
Minimize Exposure Time
a2A2448-75ucPRO Minimize Gain
Minimize Exposure Time
a2A2448-75umBAS Minimize Gain
Minimize Exposure Time
a2A2448-75umPRO Minimize Gain
Minimize Exposure Time
a2A2448-105g5cBAS Minimize Gain
Minimize Exposure Time
a2A2448-105g5mBAS Minimize Gain
Minimize Exposure Time
a2A2448-120cc Minimize Gain
Minimize Exposure Time
a2A2448-120cm Minimize Gain
Minimize Exposure Time
a2A2448-210cc Minimize Gain
Minimize Exposure Time
a2A2448-210cm Minimize Gain
Minimize Exposure Time
a2A2560-20gmSWIR Minimize Gain
Minimize Exposure Time
a2A2560-70umSWIR Minimize Gain
Minimize Exposure Time
a2A2590-22gcBAS Minimize Gain
Minimize Exposure Time
a2A2590-22gcPRO Minimize Gain
Minimize Exposure Time
a2A2590-22gmBAS Minimize Gain
Minimize Exposure Time
a2A2590-22gmPRO Minimize Gain
Minimize Exposure Time
a2A2590-60ucBAS Minimize Gain
Minimize Exposure Time
a2A2590-60ucPRO Minimize Gain
Minimize Exposure Time
a2A2590-60umBAS Minimize Gain
Minimize Exposure Time
a2A2590-60umPRO Minimize Gain
Minimize Exposure Time
a2A2600-20gcBAS Minimize Gain
Minimize Exposure Time
a2A2600-20gcPRO Minimize Gain
Minimize Exposure Time
a2A2600-20gmBAS Minimize Gain
Minimize Exposure Time
a2A2600-20gmPRO Minimize Gain
Minimize Exposure Time
a2A2600-64ucBAS Minimize Gain
Minimize Exposure Time
a2A2600-64ucPRO Minimize Gain
Minimize Exposure Time
a2A2600-64umBAS Minimize Gain
Minimize Exposure Time
a2A2600-64umPRO Minimize Gain
Minimize Exposure Time
a2A2840-14gcBAS Minimize Gain
Minimize Exposure Time
a2A2840-14gcPRO Minimize Gain
Minimize Exposure Time
a2A2840-14gmBAS Minimize Gain
Minimize Exposure Time
a2A2840-14gmPRO Minimize Gain
Minimize Exposure Time
a2A2840-14gmUV Minimize Gain
Minimize Exposure Time
a2A2840-48ucBAS Minimize Gain
Minimize Exposure Time
a2A2840-48ucPRO Minimize Gain
Minimize Exposure Time
a2A2840-48umBAS Minimize Gain
Minimize Exposure Time
a2A2840-48umPRO Minimize Gain
Minimize Exposure Time
a2A2840-48umUV Minimize Gain
Minimize Exposure Time
a2A2840-67g5cBAS Minimize Gain
Minimize Exposure Time
a2A2840-67g5mBAS Minimize Gain
Minimize Exposure Time
a2A2840-67g5mUV Minimize Gain
Minimize Exposure Time
a2A2840-86cc Minimize Gain
Minimize Exposure Time
a2A2840-86cm Minimize Gain
Minimize Exposure Time
a2A3840-13gcBAS Minimize Gain
Minimize Exposure Time
a2A3840-13gcPRO Minimize Gain
Minimize Exposure Time
a2A3840-13gmBAS Minimize Gain
Minimize Exposure Time
a2A3840-13gmPRO Minimize Gain
Minimize Exposure Time
a2A3840-45ucBAS Minimize Gain
Minimize Exposure Time
a2A3840-45ucPRO Minimize Gain
Minimize Exposure Time
a2A3840-45umBAS Minimize Gain
Minimize Exposure Time
a2A3840-45umPRO Minimize Gain
Minimize Exposure Time
a2A4096-9gcBAS Minimize Gain
Minimize Exposure Time
a2A4096-9gcPRO Minimize Gain
Minimize Exposure Time
a2A4096-9gmBAS Minimize Gain
Minimize Exposure Time
a2A4096-9gmPRO Minimize Gain
Minimize Exposure Time
a2A4096-30ucBAS Minimize Gain
Minimize Exposure Time
a2A4096-30ucPRO Minimize Gain
Minimize Exposure Time
a2A4096-30umBAS Minimize Gain
Minimize Exposure Time
a2A4096-30umPRO Minimize Gain
Minimize Exposure Time
a2A4096-44g5cBAS Minimize Gain
Minimize Exposure Time
a2A4096-44g5mBAS Minimize Gain
Minimize Exposure Time
a2A4096-67cc Minimize Gain
Minimize Exposure Time
a2A4096-67cm Minimize Gain
Minimize Exposure Time
a2A4200-12gcBAS Minimize Gain
Minimize Exposure Time
a2A4200-12gcPRO Minimize Gain
Minimize Exposure Time
a2A4200-12gmBAS Minimize Gain
Minimize Exposure Time
a2A4200-12gmPRO Minimize Gain
Minimize Exposure Time
a2A4200-40ucBAS Minimize Gain
Minimize Exposure Time
a2A4200-40ucPRO Minimize Gain
Minimize Exposure Time
a2A4200-40umBAS Minimize Gain
Minimize Exposure Time
a2A4200-40umPRO Minimize Gain
Minimize Exposure Time
a2A4504-5gcBAS Minimize Gain
Minimize Exposure Time
a2A4504-5gcPRO Minimize Gain
Minimize Exposure Time
a2A4504-5gmBAS Minimize Gain
Minimize Exposure Time
a2A4504-5gmPRO Minimize Gain
Minimize Exposure Time
a2A4504-18ucBAS Minimize Gain
Minimize Exposure Time
a2A4504-18ucPRO Minimize Gain
Minimize Exposure Time
a2A4504-18umBAS Minimize Gain
Minimize Exposure Time
a2A4504-18umPRO Minimize Gain
Minimize Exposure Time
a2A4504-27g5cBAS Minimize Gain
Minimize Exposure Time
a2A4504-27g5mBAS Minimize Gain
Minimize Exposure Time
a2A4504-42cc Minimize Gain
Minimize Exposure Time
a2A4504-42cm Minimize Gain
Minimize Exposure Time
a2A4508-6gcBAS Minimize Gain
Minimize Exposure Time
a2A4508-6gcPRO Minimize Gain
Minimize Exposure Time
a2A4508-6gmBAS Minimize Gain
Minimize Exposure Time
a2A4508-6gmPRO Minimize Gain
Minimize Exposure Time
a2A4508-20ucBAS Minimize Gain
Minimize Exposure Time
a2A4508-20ucPRO Minimize Gain
Minimize Exposure Time
a2A4508-20umBAS Minimize Gain
Minimize Exposure Time
a2A4508-20umPRO Minimize Gain
Minimize Exposure Time
a2A5320-7gcBAS Minimize Gain
Minimize Exposure Time
a2A5320-7gcPRO Minimize Gain
Minimize Exposure Time
a2A5320-7gmBAS Minimize Gain
Minimize Exposure Time
a2A5320-7gmPRO Minimize Gain
Minimize Exposure Time
a2A5320-23ucBAS Minimize Gain
Minimize Exposure Time
a2A5320-23ucPRO Minimize Gain
Minimize Exposure Time
a2A5320-23umBAS Minimize Gain
Minimize Exposure Time
a2A5320-23umPRO Minimize Gain
Minimize Exposure Time
a2A5320-34g5cBAS Minimize Gain
Minimize Exposure Time
a2A5320-34g5mBAS Minimize Gain
Minimize Exposure Time
a2A5320-52cc Minimize Gain
Minimize Exposure Time
a2A5320-52cm Minimize Gain
Minimize Exposure Time
a2A5328-4gcBAS Minimize Gain
Minimize Exposure Time
a2A5328-4gcPRO Minimize Gain
Minimize Exposure Time
a2A5328-4gmBAS Minimize Gain
Minimize Exposure Time
a2A5328-4gmPRO Minimize Gain
Minimize Exposure Time
a2A5328-15ucBAS Minimize Gain
Minimize Exposure Time
a2A5328-15ucPRO Minimize Gain
Minimize Exposure Time
a2A5328-15umBAS Minimize Gain
Minimize Exposure Time
a2A5328-15umPRO Minimize Gain
Minimize Exposure Time
a2A5328-22g5cBAS Minimize Gain
Minimize Exposure Time
a2A5328-22g5mBAS Minimize Gain
Minimize Exposure Time
a2A5328-35cc Minimize Gain
Minimize Exposure Time
a2A5328-35cm Minimize Gain
Minimize Exposure Time
acA640-121gm Gain Minimum
Exposure Minimum
acA640-300gc Gain Minimum
Exposure Minimum
acA640-300gm Gain Minimum
Exposure Minimum
acA640-750uc Minimize Gain
Minimize Exposure Time
acA640-750um Minimize Gain
Minimize Exposure Time
acA720-290gc Gain Minimum
Exposure Minimum
acA720-290gm Gain Minimum
Exposure Minimum
acA720-520uc Minimize Gain
Minimize Exposure Time
acA720-520um Minimize Gain
Minimize Exposure Time
acA800-200gc Gain Minimum
Exposure Minimum
acA800-200gm Gain Minimum
Exposure Minimum
acA800-510uc Minimize Gain
Minimize Exposure Time
acA800-510um Minimize Gain
Minimize Exposure Time
acA1280-60gc Gain Minimum
Exposure Minimum
acA1280-60gm Gain Minimum
Exposure Minimum
acA1300-60gc Gain Minimum
Exposure Minimum
acA1300-60gm Gain Minimum
Exposure Minimum
acA1300-60gmNIR Gain Minimum
Exposure Minimum
acA1300-75gc Gain Minimum
Exposure Minimum
acA1300-75gm Gain Minimum
Exposure Minimum
acA1300-200uc Minimize Gain
Minimize Exposure Time
acA1300-200um Minimize Gain
Minimize Exposure Time
acA1440-73gc Gain Minimum
Exposure Minimum
acA1440-73gm Gain Minimum
Exposure Minimum
acA1440-220uc Minimize Gain
Minimize Exposure Time
acA1440-220um Minimize Gain
Minimize Exposure Time
acA1600-20gc Gain Minimum
Exposure Minimum
acA1600-20uc Minimize Gain
Minimize Exposure Time
acA1600-60gc Gain Minimum
Exposure Minimum
acA1600-60gm Gain Minimum
Exposure Minimum
acA1920-25gc Gain Minimum
Exposure Minimum
acA1920-25gm Gain Minimum
Exposure Minimum
acA1920-25uc Minimize Gain
Minimize Exposure Time
acA1920-25um Minimize Gain
Minimize Exposure Time
acA1920-40gc Gain Minimum
Exposure Minimum
acA1920-40gm Gain Minimum
Exposure Minimum
acA1920-40uc Minimize Gain
Minimize Exposure Time
acA1920-40ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA1920-40um Minimize Gain
Minimize Exposure Time
acA1920-40umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA1920-48gc Gain Minimum
Exposure Minimum
acA1920-48gm Gain Minimum
Exposure Minimum
acA1920-50gc Gain Minimum
Exposure Minimum
acA1920-50gm Gain Minimum
Exposure Minimum
acA1920-150uc Minimize Gain
Minimize Exposure Time
acA1920-150um Minimize Gain
Minimize Exposure Time
acA1920-155uc Minimize Gain
Minimize Exposure Time
acA1920-155ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA1920-155um Minimize Gain
Minimize Exposure Time
acA1920-155umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA2000-50gc Gain Minimum
Exposure Minimum
acA2000-50gm Gain Minimum
Exposure Minimum
acA2000-165uc Minimize Gain
Minimize Exposure Time
acA2000-165um Minimize Gain
Minimize Exposure Time
acA2040-25gc Gain Minimum
Exposure Minimum
acA2040-25gm Gain Minimum
Exposure Minimum
acA2040-25gmNIR Gain Minimum
Exposure Minimum
acA2040-35gc Gain Minimum
Exposure Minimum
acA2040-35gm Gain Minimum
Exposure Minimum
acA2040-55uc Minimize Gain
Minimize Exposure Time
acA2040-55um Minimize Gain
Minimize Exposure Time
acA2040-90uc Minimize Gain
Minimize Exposure Time
acA2040-90um Minimize Gain
Minimize Exposure Time
acA2040-90umNIR Minimize Gain
Minimize Exposure Time
acA2040-120uc Minimize Gain
Minimize Exposure Time
acA2040-120um Minimize Gain
Minimize Exposure Time
acA2440-20gc Gain Minimum
Exposure Minimum
acA2440-20gm Gain Minimum
Exposure Minimum
acA2440-35uc Minimize Gain
Minimize Exposure Time
acA2440-35ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA2440-35um Minimize Gain
Minimize Exposure Time
acA2440-35umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA2440-75uc Minimize Gain
Minimize Exposure Time
acA2440-75ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA2440-75um Minimize Gain
Minimize Exposure Time
acA2440-75umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA2500-14gc Gain Minimum
Exposure Minimum
acA2500-14gm Gain Minimum
Exposure Minimum
acA2500-14uc Minimize Gain
Minimize Exposure Time
acA2500-14um Minimize Gain
Minimize Exposure Time
acA2500-20gc Gain Minimum
Exposure Minimum
acA2500-20gcMED Gain Minimum
Exposure Minimum
Gain Minimum Quick
Exposure Minimum Quick
acA2500-20gm Gain Minimum
Exposure Minimum
acA2500-20gmMED Gain Minimum
Exposure Minimum
Gain Minimum Quick
Exposure Minimum Quick
acA2500-60uc Minimize Gain
Minimize Exposure Time
acA2500-60um Minimize Gain
Minimize Exposure Time
acA3088-16gc Gain Minimum
Exposure Minimum
acA3088-16gm Gain Minimum
Exposure Minimum
acA3088-57uc Minimize Gain
Minimize Exposure Time
acA3088-57ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA3088-57um Minimize Gain
Minimize Exposure Time
acA3088-57umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA3800-10gc Gain Minimum
Exposure Minimum
acA3800-10gm Gain Minimum
Exposure Minimum
acA3800-14uc Minimize Gain
Minimize Exposure Time
acA3800-14um Minimize Gain
Minimize Exposure Time
acA4024-8gc Gain Minimum
Exposure Minimum
acA4024-8gm Gain Minimum
Exposure Minimum
acA4024-29uc Minimize Gain
Minimize Exposure Time
acA4024-29um Minimize Gain
Minimize Exposure Time
acA4096-11gc Gain Minimum
Exposure Minimum
acA4096-11gm Gain Minimum
Exposure Minimum
acA4096-30uc Minimize Gain
Minimize Exposure Time
acA4096-30ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA4096-30um Minimize Gain
Minimize Exposure Time
acA4096-30umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA4096-40uc Minimize Gain
Minimize Exposure Time
acA4096-40ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA4096-40um Minimize Gain
Minimize Exposure Time
acA4096-40umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA4112-8gc Gain Minimum
Exposure Minimum
acA4112-8gm Gain Minimum
Exposure Minimum
acA4112-20uc Minimize Gain
Minimize Exposure Time
acA4112-20ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA4112-20um Minimize Gain
Minimize Exposure Time
acA4112-20umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA4112-30uc Minimize Gain
Minimize Exposure Time
acA4112-30ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA4112-30um Minimize Gain
Minimize Exposure Time
acA4112-30umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA5472-5gc Gain Minimum
Exposure Minimum
acA5472-5gm Gain Minimum
Exposure Minimum
acA5472-17uc Minimize Gain
Minimize Exposure Time
acA5472-17ucMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
acA5472-17um Minimize Gain
Minimize Exposure Time
acA5472-17umMED Minimize Gain
Minimize Exposure Time
Minimize Gain Quick
Minimize Exposure Time Quick
boA1936-400cc Minimize Gain
Minimize Exposure Time
boA1936-400cm Minimize Gain
Minimize Exposure Time
boA2448-250cc Minimize Gain
Minimize Exposure Time
boA2448-250cm Minimize Gain
Minimize Exposure Time
boA2832-190cc Minimize Gain
Minimize Exposure Time
boA2832-190cm Minimize Gain
Minimize Exposure Time
boA4096-93cc Minimize Gain
Minimize Exposure Time
boA4096-93cm Minimize Gain
Minimize Exposure Time
boA4096-180cc Minimize Gain
Minimize Exposure Time
boA4096-180cm Minimize Gain
Minimize Exposure Time
boA4112-68cc Minimize Gain
Minimize Exposure Time
boA4112-68cm Minimize Gain
Minimize Exposure Time
boA4500-45cc Minimize Gain
Minimize Exposure Time
boA4500-45cm Minimize Gain
Minimize Exposure Time
boA4504-100cc Minimize Gain
Minimize Exposure Time
boA4504-100cm Minimize Gain
Minimize Exposure Time
boA5120-150cc Auto Function Profile feature not supported
boA5120-150cm Auto Function Profile feature not supported
boA5120-230cc Auto Function Profile feature not supported
boA5120-230cm Auto Function Profile feature not supported
boA5320-150cc Minimize Gain
Minimize Exposure Time
boA5320-150cm Minimize Gain
Minimize Exposure Time
boA5328-100cc Minimize Gain
Minimize Exposure Time
boA5328-100cm Minimize Gain
Minimize Exposure Time
boA6500-36cc Minimize Gain
Minimize Exposure Time
boA6500-36cm Minimize Gain
Minimize Exposure Time
boA8100-16cc Minimize Gain
Minimize Exposure Time
boA8100-16cm Minimize Gain
Minimize Exposure Time
boA9344-30cc Auto Function Profile feature not supported
boA9344-30cm Auto Function Profile feature not supported
boA9344-70cc Auto Function Profile feature not supported
boA9344-70cm Auto Function Profile feature not supported
boA13440-17cm Auto Function Profile feature not supported
daA720-520uc Minimize Gain
Minimize Exposure Time
daA720-520um Minimize Gain
Minimize Exposure Time
daA1280-54uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA1280-54um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA1440-220uc Minimize Gain
Minimize Exposure Time
daA1440-220um Minimize Gain
Minimize Exposure Time
daA1600-60uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA1600-60um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA1920-15um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA1920-30uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA1920-30um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA1920-160uc Minimize Gain
Minimize Exposure Time
daA1920-160um Minimize Gain
Minimize Exposure Time
daA2448-70uc Minimize Gain
Minimize Exposure Time
daA2448-70um Minimize Gain
Minimize Exposure Time
daA2500-14uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA2500-14um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
daA3840-45uc Minimize Gain
Minimize Exposure Time
daA3840-45um Minimize Gain
Minimize Exposure Time
dmA720-290gc Minimize Gain
Minimize Exposure Time
dmA720-290gm Minimize Gain
Minimize Exposure Time
dmA1440-73gc Minimize Gain
Minimize Exposure Time
dmA1440-73gm Minimize Gain
Minimize Exposure Time
dmA1920-51gc Minimize Gain
Minimize Exposure Time
dmA1920-51gm Minimize Gain
Minimize Exposure Time
puA1280-54uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
puA1280-54um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
puA1600-60uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
puA1600-60um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
puA1920-30uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
puA1920-30um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
puA2500-14uc Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
puA2500-14um Minimize Gain
Minimize Exposure Time
Smart
Anti-Flicker 50 Hz
Anti-Flicker 60 Hz
r2L2048-29gc Auto Function Profile feature not supported
r2L2048-58gm Auto Function Profile feature not supported
r2L2048-62cc Auto Function Profile feature not supported
r2L2048-62g5c Auto Function Profile feature not supported
r2L2048-172cm Auto Function Profile feature not supported
r2L2048-172g5m Auto Function Profile feature not supported
r2L4096-14gc Auto Function Profile feature not supported
r2L4096-29gm Auto Function Profile feature not supported
r2L4096-42cc Auto Function Profile feature not supported
r2L4096-42g5c Auto Function Profile feature not supported
r2L4096-84cm Auto Function Profile feature not supported
r2L4096-84g5m Auto Function Profile feature not supported
r2L8192-200cm Auto Function Profile feature not supported
r2L16384-120cm Auto Function Profile feature not supported

Sample Code#

ace Classic/U/L GigE Cameras#
// Set the auto function profile to Gain Minimum
camera.AutoFunctionProfile.SetValue(AutoFunctionProfile_GainMinimum);
// Set the auto function profile to Exposure Minimum
camera.AutoFunctionProfile.SetValue(AutoFunctionProfile_ExposureMinimum);
// Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
camera.GainAuto.SetValue(GainAuto_Continuous);
camera.ExposureAuto.SetValue(ExposureAuto_Continuous);
INodeMap& nodemap = camera.GetNodeMap();
// Set the auto function profile to Gain Minimum
CEnumParameter(nodemap, "AutoFunctionProfile").SetValue("GainMinimum");
// Set the auto function profile to Exposure Minimum
CEnumParameter(nodemap, "AutoFunctionProfile").SetValue("ExposureMinimum");
// Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
CEnumParameter(nodemap, "GainAuto").SetValue("Continuous");
CEnumParameter(nodemap, "ExposureAuto").SetValue("Continuous");
// Set the auto function profile to Gain Minimum
camera.Parameters[PLCamera.AutoFunctionProfile].SetValue(PLCamera.AutoFunctionProfile.GainMinimum);
// Set the auto function profile to Exposure Minimum
camera.Parameters[PLCamera.AutoFunctionProfile].SetValue(PLCamera.AutoFunctionProfile.ExposureMinimum);
// Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
camera.Parameters[PLCamera.GainAuto].SetValue(PLCamera.GainAuto.Continuous);
camera.Parameters[PLCamera.ExposureAuto].SetValue(PLCamera.ExposureAuto.Continuous);
/* Macro to check for errors */
#define CHECK(errc) if (GENAPI_E_OK != errc) printErrorAndExit(errc)
GENAPIC_RESULT errRes = GENAPI_E_OK;  /* Return value of pylon methods */
/* Set the auto function profile to Gain Minimum */
errRes = PylonDeviceFeatureFromString(hdev, "AutoFunctionProfile", "GainMinimum");
CHECK(errRes);
/* Set the auto function profile to Exposure Minimum */
errRes = PylonDeviceFeatureFromString(hdev, "AutoFunctionProfile", "ExposureMinimum");
CHECK(errRes);
/* Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous */
errRes = PylonDeviceFeatureFromString(hdev, "GainAuto", "Continuous");
CHECK(errRes);
errRes = PylonDeviceFeatureFromString(hdev, "ExposureAuto", "Continuous");
CHECK(errRes);
# Set the auto function profile to Gain Minimum
camera.AutoFunctionProfile.Value = "GainMinimum"
# Set the auto function profile to Exposure Minimum
camera.AutoFunctionProfile.Value = "ExposureMinimum"
# Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
camera.GainAuto.Value = "Continuous"
camera.ExposureAuto.Value = "Continuous"
Other Cameras#
// Set the auto function profile to Minimize Gain
camera.AutoFunctionProfile.SetValue(AutoFunctionProfile_MinimizeGain);
// Set the auto function profile to Minimize Exposure Time
camera.AutoFunctionProfile.SetValue(AutoFunctionProfile_MinimizeExposureTime);
// Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
camera.GainAuto.SetValue(GainAuto_Continuous);
camera.ExposureAuto.SetValue(ExposureAuto_Continuous);
INodeMap& nodemap = camera.GetNodeMap();
// Set the auto function profile to Minimize Gain
CEnumParameter(nodemap, "AutoFunctionProfile").SetValue("MinimizeGain");
// Set the auto function profile to Minimize Exposure Time
CEnumParameter(nodemap, "AutoFunctionProfile").SetValue("MinimizeExposureTime");
// Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
CEnumParameter(nodemap, "GainAuto").SetValue("Continuous");
CEnumParameter(nodemap, "ExposureAuto").SetValue("Continuous");
// Set the auto function profile to Minimize Gain
camera.Parameters[PLCamera.AutoFunctionProfile].SetValue(PLCamera.AutoFunctionProfile.MinimizeGain);
// Set the auto function profile to Minimize Exposure Time
camera.Parameters[PLCamera.AutoFunctionProfile].SetValue(PLCamera.AutoFunctionProfile.MinimizeExposureTime);
// Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
camera.Parameters[PLCamera.GainAuto].SetValue(PLCamera.GainAuto.Continuous);
camera.Parameters[PLCamera.ExposureAuto].SetValue(PLCamera.ExposureAuto.Continuous);
/* Macro to check for errors */
#define CHECK(errc) if (GENAPI_E_OK != errc) printErrorAndExit(errc)
GENAPIC_RESULT errRes = GENAPI_E_OK;  /* Return value of pylon methods */
/* Set the auto function profile to Minimize Gain */
errRes = PylonDeviceFeatureFromString(hdev, "AutoFunctionProfile", "MinimizeGain");
CHECK(errRes);
/* Set the auto function profile to Minimize Exposure Time */
errRes = PylonDeviceFeatureFromString(hdev, "AutoFunctionProfile", "MinimizeExposureTime");
CHECK(errRes);
/* Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous */
errRes = PylonDeviceFeatureFromString(hdev, "GainAuto", "Continuous");
CHECK(errRes);
errRes = PylonDeviceFeatureFromString(hdev, "ExposureAuto", "Continuous");
CHECK(errRes);
# Set the auto function profile to Minimize Gain
camera.AutoFunctionProfile.Value = "MinimizeGain"
# Set the auto function profile to Minimize Exposure Time
camera.AutoFunctionProfile.Value = "MinimizeExposureTime"
# Enable Gain and Exposure Auto auto functions and set the operating mode to Continuous
camera.GainAuto.Value = "Continuous"
camera.ExposureAuto.Value = "Continuous"

You can also use the pylon Viewer to easily set the parameters.