Skip to content

Basler Standard Light Flat Dome-200x300-x#

Basler Standard Flat Dome Lights can be used in various applications for bright field lighting of slightly objects.

Basler Standard Light Flat Dome

Key Features#

  • Internal LED controller with 2 operating modes
  • Compatible with Basler SLP Strobe Controller
  • Preconfigured hardware components
  • Various sizes and LED colors

General Specifications#

Basler Standard Light Flat Dome-200x300-Red Basler Standard Light Flat Dome-200x300-White Basler Standard Light Flat Dome-200x300-Blue Basler Standard Light Flat Dome-200x300-Infrared
Order Number 2200001102 2200001101 2200001103 2200001104
LED Color Red White Blue Infrared
Luminous Area 200 x 300 mm 200 x 300 mm 200 x 300 mm 200 x 300 mm
Lens Hole (diameter) 45 mm 45 mm 45 mm 45 mm
Recommended Light Working Distance 150–500 mm 150–500 mm 150–500 mm 150–500 mm
Basler Standard Light Flat Dome-200x300-x
Conformity CE (includes RoHS), FCC, IP54, UKCA

LED Specifications#

Flat Dome Light Series 200x300-x
Luminous Power of
White LEDs (lumen)
2610
Radiant Power of
Red LEDs (mW)
7690
Radiant Power of
IR LEDs (mW)
3700

Electrical Specifications#

Flat Dome Light Series 200x300-x
Required Power for Voltage Control Mode 24 VDC ± 10 %,
28 W
Required Current for Current Control Mode Red, White, and Blue: 1500 mA
Infrared: 1800 mA
Recommended max. LED Current for Strobe Mode
(50 % Duty Cycle, 100 ms Pulses)
Red, White, and Blue: 3000 mA
Infrared: Must never be used.
Recommended max. LED Current for Strobe Mode
(25 % Duty Cycle, 20 ms Pulses)
Red, White, and Blue: 4500 mA
Infrared: Must never be used.
Recommended max. LED Current for Strobe Mode
(10 % Duty Cycle, 5 ms Pulses)
Red, White, and Blue: 6000 mA
Infrared: 3600 mA
Infrared only: Recommended max. LED Current, Strobe Mode 1 %
(1 % Duty Cycle, 100 µs Pulses)
5400 mA
Recommended min. Flash Time in Strobe Mode 100 µs

Mechanical Specifications#

Flat Dome Light Series 200x300-x
Dimensions
(H x W x D)
240 x 330 x 12 mm
Weight 1600 g
Material Black anodized aluminum housing with PMMA light cover
Connector M8 socket, 4-pin male connector

Flat Dome Light Dimensions#

Basler Standard Flat Dome Light 200x300x

Connector Pin Numbering#

Connector Pin Numbering Basler Standard Light

Info

The pin assignment of the light's connector differs depending on whether you want to use the internal or an external controller. For more information, see the respective tables in the Installation chapter.

Environmental Requirements#

Temperature During Operation 10–30 °C (50–86 °F)
Humidity During Operation 30–70 %

Performance Charts#

Peak Illuminance versus Light Working Distance (LWD)#

Peak Illuminance versus Light Working Distance (LWD)

Info

Diagram is based on the following reference model: BSL Flat Dome-200x300-White.

Spectrum#

Spectrum

Uniformity#

Uniformity

Info

The values in the graph above are measured in mm.

Uniformity Intensity