Building the Design

Case Sensitivity and Slashes

 

The following commands are case sensitive. Use forward slashes to indicate pathes.

   

Parameter Notation Syntax

 

The notation used below for describing the parameters of individual commands is based on the Wirth Syntax Notation (WSN) :

  • Parameter names in curly brackets denote that you can specify no value, one value, or multiple values for this parameter in the command line.
  • Parameter names in square brackets denote optional parameters.
   

Command

Parameters

Description

Drc

[SaveLogfileName]

 

Command for starting the first level of the Design Rule Check (DRC 1).

To get a log output, you can optionally specify the path to and the name of an html log file (*.html) in parameter [SaveLogfileName].

Drc2

Name

Platform

Command for starting the second level of the Design Rule Check (DRC 2).

To get a log output, you can optionally specify the path to and the name of an html log file (*.html) in parameter [SaveLogfileName].

SelectBuildConfiguration

 

ConfigurationName

Command for selecting a saved build configuration as active build configuration.

Specify the name of the desired build configuration in parameter ConfigurationName.

  • To get an overview over all available build configurations, enter SelectBuildConfiguration ? - a list of the names of all available build configurations is returned. The currently selected build configuration is displayed in the first entry of the list.
    Example:

The command returns the name of the currently selected build configuration. Via this return value you can check if your re-setting the build configuration was successful.
Example:


Build

[SaveLogfilename

[MaxTime] ]

Command for starting the build flow.

To get a log output, you can optionally specify the path to and the name of an html log file (*.html) in parameter [SaveLogfileName].

To set a time limit for the build process, you can optionally specify the the maximum build time in parameter [MaxTime] (in hours). Parameter [MaxTime] is of type floating point. This way, you can specify fractions of an hour. The default setting for [MaxTime] is 24 hours.

Example for a command creating log file build_log.html and specifying the maximum Build time as ½ hour: 

Build build_log.html 0.5