The ImgIn Interface of the eVA IP Core
The image streaming ports ImgIn are general purpose image communication interfaces for writing image data from surrounding FPGA logic into the VA IP Core. The ImgIn ports consist of a simple FIFO interface plus additional parameter ports. The interface ports are thoroughly parameterized. In addition to the existing parameters, you can define additional registers for forwarding parameters to the connected FPGA logic.
Image data enters the VA IP Core by interface ports of type ImgIn. Multiple classes of ImgIn ports may be defined and for each of them multiple instances are possible.
Port layout for image input interface |
|
The following table describes the interface signals where PORTID is the name of the corresponding image input port class and X is a port number for differentiating several ports of the same class:
|
Port |
Direction |
Width |
Description |
|
iPORTIDXClk |
In |
1 |
Clock for writing to FIFO. This input is ignored when the port is configured for synchronous communication. (ImgIn Interface configuration is described Defining ImgIn Interface Classes) |
|
ivPORTIDXData |
In |
PORTIDWidth |
Write data (interpreted as pixel data, or as and-of-line or and-of-frame flag) |
|
iPORTIDXValid |
In |
1 |
Perform write access |
|
iPORTIDXEndOfLine |
In |
1 |
Signal current write access as end-of-line notification. Write data is then not interpreted as pixel data. |
|
iPORTIDXEndOfFrame |
In |
1 |
Signals end of frame. If this flag is activated data doesn’t contain pixel values. The end-of-frame signal must coincide with the end-of-line signal. |
|
oPORTIDXFIFOFull |
Out |
1 |
Input FIFO is full, no further data is accepted. |
|
ovPORTIDXFIFOCnt |
Out |
Ceil Log2( PORTIDFIFODepth)1 |
Number of words in input FIFO. This signal can be used to generate FIFO flags like “Almost Full”. |
|
oPORTIDXReset |
Out |
1 |
Reset signal of the process |
|
oPORTIDXEnable |
Out |
1 |
Enable signal of the process |
|
ovPORTIDX_PARNAME_D |
Out |
S |
Data of the parameter PARNAME. S depends on the selected bit width. This signal is generated for each parameter defined. |
|
oPORTIDX_PARNAME_Upd |
Out |
1 |
This signal is set to ‘1’ for one clock cycle when the parameter PARNAME is updated from the runtime software. This signal is generated for each parameter defined. |
|
ovPORTIDX_FID_D |
Out |
Ceil Log2(N)2 |
Predefined parameter which notifies about the current image data format. N is the number of image formats specified for this port. |
The following figure shows the timing of image communication through an ImgIn interface for a simple example where a frame with two lines of three 32-bit gray pixel values is transferred. In the waveform the name part PORTIDX has been substituted by ‘imgin ‘.
Waveform illustrating the protocol on an image input port