Skip to content

Reverse X and Reverse Y#

The Reverse X and Reverse Y camera features allow you to mirror acquired images horizontally, vertically, or both.

Reverse X is available on all camera models. Reverse Y is available on selected camera models.

Using the Feature#

Enabling Reverse X#

To enable Reverse X, set the ReverseX parameter to true.

The camera mirrors the image horizontally:

Reverse X Mirror Imaging

Enabling Reverse Y#

On some camera models, the Reverse Y feature is also available.

To enable Reverse Y, set the ReverseY parameter to true.

The camera mirrors the image vertically:

Reverse Y Mirror Imaging

Using Image ROIs or Auto Function ROIs with Reverse X or Reverse Y#

If you have specified an image ROI or auto function ROI while using Reverse X or Reverse Y, it depends on your camera model whether the position of the ROI relative to the sensor adapts to the mirrored image or not.

Self-Adapting Image ROI or Auto Function ROI#

On some camera models, the position of the ROI relative to the sensor adapts to the mirrored image when you use the Reverse X or the Reverse Y feature. The camera captures the same portions of the image.

Adapting of ROI with Reverse X Mirror Imaging

Adapting of ROI with Reverse Y Mirror Imaging

No Self-Adapting Image ROI or Auto Function ROI#

On some camera models, the position of the ROI relative to the sensor remains the same. As a consequence, the camera captures different portions of the image depending on whether the Reverse X or the Reverse Y feature are enabled:

No Adapting of ROI with Reverse X Mirror Imaging

No Adapting of ROI with Reverse Y Mirror Imaging

Effective Bayer Filter Alignments (Color Cameras Only)#

Depending on your camera model, the Bayer filter alignment changes when Reverse X, Reverse Y, or both are used.

For example, if you use a camera with a physical Bayer BG filter alignment and enable Reverse X, the actual Bayer filter alignment will be Bayer GB. The PixelFormat parameter value changes accordingly.

Specifics#

Show all camera models

Camera Model Available Directions Self-Adapting Image ROI or Auto Function ROI Changes in Bayer Filter Alignment
a2A1920-51gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A1920-51gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A1920-51gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A1920-51gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A1920-160ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A1920-160ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A1920-160umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A1920-160umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2448-23gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2448-23gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2448-23gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2448-23gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2448-75ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2448-75ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2448-75umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2448-75umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2590-22gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2590-22gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2590-22gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2590-22gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2590-60ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2590-60ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2590-60umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2590-60umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2840-14gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2840-14gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2840-14gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2840-14gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2840-48ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2840-48ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A2840-48umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A2840-48umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A3840-13gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A3840-13gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A3840-13gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A3840-13gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A3840-45ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A3840-45ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A3840-45umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A3840-45umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4096-9gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4096-9gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4096-9gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4096-9gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4096-30ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4096-30ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4096-30umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4096-30umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4504-5gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4504-5gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4504-5gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4504-5gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4504-18ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4504-18ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A4504-18umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A4504-18umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5320-7gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5320-7gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5320-7gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5320-7gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5320-23ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5320-23ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5320-23umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5320-23umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5328-4gcBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5328-4gcPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5328-4gmBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5328-4gmPRO Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5328-15ucBAS Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5328-15ucPRO Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
a2A5328-15umBAS Reverse X
Reverse Y
Yes N/A (mono camera)
a2A5328-15umPRO Reverse X
Reverse Y
Yes N/A (mono camera)
acA640-90gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA640-90gm Reverse X No N/A (mono camera)
acA640-90uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA640-90um Reverse X No N/A (mono camera)
acA640-120gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA640-120gm Reverse X No N/A (mono camera)
acA640-120uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA640-120um Reverse X No N/A (mono camera)
acA640-121gm Reverse X No N/A (mono camera)
acA640-300gc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA640-300gm Reverse X
Reverse Y
No N/A (mono camera)
acA640-750uc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA640-750um Reverse X
Reverse Y
No N/A (mono camera)
acA720-290gc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA720-290gm Reverse X
Reverse Y
No N/A (mono camera)
acA720-520uc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA720-520um Reverse X
Reverse Y
No N/A (mono camera)
acA780-75gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA780-75gm Reverse X No N/A (mono camera)
acA800-200gc Reverse X
Reverse Y
No N/A (mono camera)
acA800-200gm Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA800-510uc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA800-510um Reverse X
Reverse Y
No N/A (mono camera)
acA1280-60gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1280-60gm Reverse X No N/A (mono camera)
acA1300-22gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1300-22gm Reverse X No N/A (mono camera)
acA1300-30gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1300-30gm Reverse X No N/A (mono camera)
acA1300-30uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1300-30um Reverse X No N/A (mono camera)
acA1300-60gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1300-60gm Reverse X No N/A (mono camera)
acA1300-60gmNIR Reverse X No N/A (mono camera)
acA1300-75gc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA1300-75gm Reverse X
Reverse Y
No N/A (mono camera)
acA1300-200uc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA1300-200um Reverse X
Reverse Y
No N/A (mono camera)
acA1440-73gc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA1440-73gm Reverse X
Reverse Y
No N/A (mono camera)
acA1440-220uc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA1440-220um Reverse X
Reverse Y
No N/A (mono camera)
acA1600-20gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1600-20gm Reverse X No N/A (mono camera)
acA1600-20uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1600-20um Reverse X No N/A (mono camera)
acA1600-60gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1600-60gm Reverse X No N/A (mono camera)
acA1920-25gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1920-25gm Reverse X No N/A (mono camera)
acA1920-25uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA1920-25um Reverse X No N/A (mono camera)
acA1920-40gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA1920-40gm Reverse X
Reverse Y
No N/A (mono camera)
acA1920-40uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA1920-40ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA1920-40um Reverse X
Reverse Y
No N/A (mono camera)
acA1920-40umMED Reverse X
Reverse Y
No N/A (mono camera)
acA1920-48gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA1920-48gm Reverse X
Reverse Y
No N/A (mono camera)
acA1920-50gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA1920-50gm Reverse X
Reverse Y
No N/A (mono camera)
acA1920-150uc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA1920-150um Reverse X
Reverse Y
No N/A (mono camera)
acA1920-155uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA1920-155ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA1920-155um Reverse X
Reverse Y
No N/A (mono camera)
acA1920-155umMED Reverse X
Reverse Y
No N/A (mono camera)
acA2000-50gc Reverse X
Reverse Y
No Reverse X and Reverse Y don't affect Bayer filter alignment
acA2000-50gm Reverse X
Reverse Y
No N/A (mono camera)
acA2000-50gmNIR Reverse X
Reverse Y
No N/A (mono camera)
acA2000-165uc Reverse X
Reverse Y
No Reverse X and Reverse Y don't affect Bayer filter alignment
acA2000-165um Reverse X
Reverse Y
No N/A (mono camera)
acA2000-165umNIR Reverse X
Reverse Y
No N/A (mono camera)
acA2040-25gc Reverse X
Reverse Y
No Reverse X and Reverse Y don't affect Bayer filter alignment
acA2040-25gm Reverse X
Reverse Y
No N/A (mono camera)
acA2040-25gmNIR Reverse X
Reverse Y
No N/A (mono camera)
acA2040-35gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2040-35gm Reverse X
Reverse Y
No N/A (mono camera)
acA2040-55uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2040-55um Reverse X
Reverse Y
No N/A (mono camera)
acA2040-90uc Reverse X
Reverse Y
No Reverse X and Reverse Y don't affect Bayer filter alignment
acA2040-90um Reverse X
Reverse Y
No N/A (mono camera)
acA2040-90umNIR Reverse X
Reverse Y
No N/A (mono camera)
acA2040-120uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2040-120um Reverse X
Reverse Y
No N/A (mono camera)
acA2440-20gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2440-20gm Reverse X
Reverse Y
No N/A (mono camera)
acA2440-35uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2440-35ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2440-35um Reverse X
Reverse Y
No N/A (mono camera)
acA2440-35umMED Reverse X
Reverse Y
No N/A (mono camera)
acA2440-75uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2440-75ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA2440-75um Reverse X
Reverse Y
No N/A (mono camera)
acA2440-75umMED Reverse X
Reverse Y
No N/A (mono camera)
acA2500-14gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA2500-14gm Reverse X No N/A (mono camera)
acA2500-14uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA2500-14um Reverse X No N/A (mono camera)
acA2500-20gc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA2500-20gcMED Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA2500-20gm Reverse X
Reverse Y
No N/A (mono camera)
acA2500-20gmMED Reverse X
Reverse Y
No N/A (mono camera)
acA2500-60uc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA2500-60um Reverse X
Reverse Y
No N/A (mono camera)
acA3088-16gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA3088-16gm Reverse X
Reverse Y
No N/A (mono camera)
acA3088-57uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA3088-57ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA3088-57um Reverse X
Reverse Y
No N/A (mono camera)
acA3088-57umMED Reverse X
Reverse Y
No N/A (mono camera)
acA3800-10gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA3800-10gm Reverse X No N/A (mono camera)
acA3800-14uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA3800-14um Reverse X No N/A (mono camera)
acA4024-8gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4024-8gm Reverse X
Reverse Y
No N/A (mono camera)
acA4024-29uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4024-29um Reverse X
Reverse Y
No N/A (mono camera)
acA4096-11gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4096-11gm Reverse X
Reverse Y
No N/A (mono camera)
acA4096-30uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4096-30ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4096-30um Reverse X
Reverse Y
No N/A (mono camera)
acA4096-30umMED Reverse X
Reverse Y
No N/A (mono camera)
acA4096-40uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4096-40ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4096-40um Reverse X
Reverse Y
No N/A (mono camera)
acA4096-40umMED Reverse X
Reverse Y
No N/A (mono camera)
acA4112-8gc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4112-8gm Reverse X
Reverse Y
No N/A (mono camera)
acA4112-20uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4112-20ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4112-20um Reverse X
Reverse Y
No N/A (mono camera)
acA4112-20umMED Reverse X
Reverse Y
No N/A (mono camera)
acA4112-30uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4112-30ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA4112-30um Reverse X
Reverse Y
No N/A (mono camera)
acA4112-30umMED Reverse X
Reverse Y
No N/A (mono camera)
acA4600-7gc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA4600-10uc Reverse X No Reverse X and Reverse Y don't affect Bayer filter alignment
acA5472-5gc Reverse X
Reverse Y
No Default: BG
Reverse X enabled: GB
Reverse Y enabled: GR
Reverse X and Reverse Y enabled: RG
acA5472-5gm Reverse X
Reverse Y
No N/A (mono camera)
acA5472-17uc Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA5472-17ucMED Reverse X
Reverse Y
No Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
acA5472-17um Reverse X
Reverse Y
No N/A (mono camera)
acA5472-17umMED Reverse X
Reverse Y
No N/A (mono camera)
boA4096-93cc Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
boA4096-93cm Reverse X
Reverse Y
Yes N/A (mono camera)
boA4112-68cc Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
boA4112-68cm Reverse X
Reverse Y
Yes N/A (mono camera)
boA4500-45cc Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
boA4500-45cm Reverse X
Reverse Y
Yes N/A (mono camera)
boA6500-36cc Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
boA6500-36cm Reverse X
Reverse Y
Yes N/A (mono camera)
boA8100-16cc Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
boA8100-16cm Reverse X
Reverse Y
Yes N/A (mono camera)
daA1280-54lc Reverse X
Reverse Y
No Reverse X and Reverse Y don't affect Bayer filter alignment
daA1280-54lm Reverse X
Reverse Y
No N/A (mono camera)
daA1280-54uc Reverse X
Reverse Y
No Reverse X and Reverse Y don't affect Bayer filter alignment
daA1280-54um Reverse X
Reverse Y
No N/A (mono camera)
daA1600-60lc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
daA1600-60lm Reverse X
Reverse Y
No N/A (mono camera)
daA1600-60uc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
daA1600-60um Reverse X
Reverse Y
No N/A (mono camera)
daA1920-15um Reverse X
Reverse Y
No N/A (mono camera)
daA1920-30uc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
daA1920-30um Reverse X
Reverse Y
No N/A (mono camera)
daA1920-160uc Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
daA1920-160um Reverse X
Reverse Y
Yes N/A (mono camera)
daA2500-14lc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
daA2500-14lm Reverse X
Reverse Y
No N/A (mono camera)
daA2500-14uc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
daA2500-14um Reverse X
Reverse Y
No N/A (mono camera)
daA3840-45uc Reverse X
Reverse Y
Yes Default: RG
Reverse X enabled: GR
Reverse Y enabled: GB
Reverse X and Reverse Y enabled: BG
daA3840-45um Reverse X
Reverse Y
Yes N/A (mono camera)
puA1280-54uc Reverse X
Reverse Y
No Reverse X and Reverse Y don't affect Bayer filter alignment
puA1280-54um Reverse X
Reverse Y
No N/A (mono camera)
puA1600-60uc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
puA1600-60um Reverse X
Reverse Y
No N/A (mono camera)
puA1920-30uc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
puA1920-30um Reverse X
Reverse Y
No N/A (mono camera)
puA2500-14uc Reverse X
Reverse Y
No Default: GB
Reverse X enabled: BG
Reverse Y enabled: RG
Reverse X and Reverse Y enabled: GR
puA2500-14um Reverse X
Reverse Y
No N/A (mono camera)

Sample Code#

// Enable Reverse X
camera.ReverseX.SetValue(true);
// Enable Reverse Y, if available
camera.ReverseY.SetValue(true);
INodeMap& nodemap = camera.GetNodeMap();
// Enable Reverse X
CBooleanParameter(nodemap, "ReverseX").SetValue(true);
// Enable Reverse Y, if available
CBooleanParameter(nodemap, "ReverseY").SetValue(true);
// Enable Reverse X
camera.Parameters[PLCamera.ReverseX].SetValue(true);
// Enable Reverse Y, if available
camera.Parameters[PLCamera.ReverseY].SetValue(true);
/* Macro to check for errors */
#define CHECK(errc) if (GENAPI_E_OK != errc) printErrorAndExit(errc)
GENAPIC_RESULT errRes = GENAPI_E_OK;  /* Return value of pylon methods */
/* Enable Reverse X */
errRes = PylonDeviceSetBooleanFeature(hdev, "ReverseX", 1);
CHECK(errRes);
/* Enable Reverse Y, if available */
errRes = PylonDeviceSetBooleanFeature(hdev, "ReverseY", 1);
CHECK(errRes);

You can also use the pylon Viewer to easily set the parameters.

Back to top