Skip to content
STAGING SERVER
DEVELOPMENT SERVER

Basler Light Back-200x200-x#

Basler Backlights can be placed closely behind an object, e.g., for measuring outlines.

Basler Light Back

Key Features#

  • Intelligent Light Control (ILC): Direct light control via Basler camera, eliminating the need for an external light controller.
  • Integrated LED driver with two light control modes:
  • Overdrive option in both light control modes:
    Increased light output without requiring additional hardware (see Overdriving Light Devices)
  • Automatic light detection: Camera automatically identifies the connected Basler Light and applies appropriate operating and protection settings.
  • GenICam-compliant control via Basler cameras: Full control of brightness, strobe and continuous-light operation directly from a Basler camera using any GenICam-compatible software, such as the pylon Software Suite
  • Integrated protection mechanisms: Over-triggering and thermal overload protection ensure reliable operation and protect the light throughout its service life.
  • Support for external controllers: Can also be operated in External Control Mode via any external light controller.

Legacy Lights and New Basler Lights#

Info

Legacy Basler Lights and new Basler Lights:

  • Earlier generations of Basler Lights were lights without ILC (without intelligent light control). These lights required a separate controller for light control.
    Documentation for legacy Basler lights without ILC is no longer included in the current Basler Product Documentation. If you need information about these products, refer to the offline documentation of an earlier release, that you can download by clicking here.
  • To determine which type of light is installed, check the revision number marked on the Basler Light (e.g., 2200000841-05). The last two digits following the order number indicate the light's revision. Revision 05 and later identify Basler Lights with Intelligent Light Control (ILC), i.e., with an integrated controller. Revision numbers below 05 identify legacy Basler Lights without ILC and therefore without an integrated controller.

Pin Assignment Changes in Light Revision 05#

Info

The pin assignment has changed from legacy Basler Lights without intelligent light control (ILC) to current Basler Lights with ILC.

When You Need to Adapt the Wiring

  • If a legacy Basler Light is replaced with a new Basler Light with ILC (Intelligent Light Control) and an external controller is used (Basler SLP Controller or a third-party controller), the pin assignment must be adjusted accordingly. This is necessary because the pin assignment of Basler Lights with ILC differs from that of legacy Basler Lights.
    If the legacy pin assignment is used, the new light will not turn on.
  • Verify that you are using the correct pin assignment when connecting the light.

Further Information

General Specifications#

Basler Light Back-200x200-Red Basler Light Back-200x200-White Basler Light Back-200x200-Blue Basler Light Back-200x200-Infrared
Order Number, IP54 Lights 2200000832 2200000728 2200000801 2200000863
Peak Wavelength 625 nm - 465 nm 850 nm
Color Temperature - 5000 K - -
LED Color Red White Blue Infrared
Luminous Area 200 x 200 mm 200 x 200 mm 200 x 200 mm 200 x 200 mm
Recommended Light Working Distance 1–100 mm 1–100 mm 1–100 mm 1–100 mm
Risk Class (according to IEC 62471) Exempt Exempt Exempt Exempt
Basler Light Back-200x200-x
Conformity CE (includes RoHS), FCC, IP54, UKCA
Certificates for your light model
For more information, see the Compliance section of the Basler website.

LED Specifications#

Backlight Series 200x200x
Illuminance of
White LEDs
at 0 mm distance
64 klux

Values are approximate with ± 7 % tolerance.

Electrical Specifications#

If not indicated otherwise,
the values are valid
for IP54 and IP67 lights.
White,
5000 K
Red,
625 nm
Blue,
465 nm
IR,
850 nm
Required Voltage 24 VDC
± 5 %
24 VDC
± 5 %
24 VDC
± 5 %
24 VDC
± 5 %
Required Power for
Continuous Light
23.9 W 17.1 W 23.6 W 19.7 W
Max. LED Current for
Continuous Light
(100 % Brightness)
1200 mA 1200 mA 1200 mA 1800 mA
Overdrive Operation Ex. 1:
Max. LED Current, Duty Cycle (%),
Max. Pulse Width
1800 mA,
60 %,
200 ms
1800 mA,
60 %,
200 ms
1800 mA,
60 %,
200 ms
2700 mA,
40 %,
10 ms
Overdrive Operation Ex. 2:
Max. LED Current, Duty Cycle (%),
Max. Pulse Width
2400 mA,
40 %,
100 ms
2400 mA,
40 %,
100 ms
2400 mA,
40 %,
100 ms
3600 mA,
20 %,
5 ms
Overdrive Operation Ex. 3:
Max. LED Current, Duty Cycle (%),
Max. Pulse Width
3600 mA,
20 %,
50 ms
3600 mA,
20 %,
50 ms
3600 mA,
20 %,
50 ms
5400 mA,
10 %,
1 ms
Overdrive Operation Ex. 4:
Max. LED Current, Duty Cycle (%),
Max. Pulse Width
4000 mA,
10 %,
10 ms
4000 mA,
10 %,
10 ms
4000 mA,
10 %,
10 ms
6000 mA,
5 %,
200 μs
Recommended Min. Flash Time in
Overdrive Operation (see info below)
100 μs 100 μs 100 μs 100 μs

Info

  • The examples 1 to 4 in the table above are reference limit values only.
    Lower values for LED current, duty cycle and maximum pulse width are also possible.
  • About the recommended minimum flash time in overdrive operation: The latency between the trigger signal and the LED light going on is about maximum 30 μs. Therefore, the minimum recommended flash time in the table is 100 μs.

Mechanical Specifications#

Backlight Series 200x200x
Dimensions
(H x W x D)
220 x 250 x 12 mm
Weight 1100 g
Material Black anodized aluminum housing with PMMA light cover
Connector M8 socket, 4-pin male connector

Backlight Dimensions#

Basler Light Back 200x200x

Connector Pin Numbering#

Connector Pin Numbering Basler Light

The current Basler Light uses the M8 4-pin connector model from CONEC (article no. 42-01033).

Info

The pin assignment of the light connector depends on whether the light is operated using its integrated controller (internal control) or an external controller. For details, refer to the relevant tables in the topics of the Controlling Basler Lights section:

Environmental Requirements#

Temperature During Operation 10–30 °C (50–86 °F) / 45 °C (113 °F)a
Humidity During Operation 30–70 %

  1. For steady light operation without additional heat dissipation measures, a maximum of 30 °C (86 °F) is recommended. For a maximum of 45 °C (113 °F), heat dissipation measures are mandatory.
    For flash light operation with a maximum 10 % duty cycle, a maximum of 45 °C (113 °F) is also permissible.

Performance Charts#

Peak Illuminance versus Light Working Distance (LWD)#

Peak Illuminance versus Light Working Distance (LWD)

Info

Diagram is based on the following reference model: BL Back-200x200-White.

Spectrum#

Spectrum

Uniformity#

Uniformity

Info

The values in the graph above are measured in mm.

Uniformity Intensity