Skip to content
STAGING SERVER
DEVELOPMENT SERVER

Basler Light Bar-17x100-UV#

Basler Bar Lights can be used in various applications, e.g., for bright field lighting applications in the short-wave infrared (SWIR) light range.

Basler Light Bar UV

Info

The photo may slightly differ in appearance from the actual product.

Key Features#

  • Internal LED controller with 2 operating modes
  • Compatible with Basler SLP Strobe Controller
  • Preconfigured hardware components
  • Various sizes and wavelength ranges

General Specifications#

Basler Light Bar-17x100-UV365 Basler Light Bar-17x100-UV395
Order No. 2200002518 2200002519
Peak Wavelength near 365 nm near 395 nm
Luminous Area 17 x 100 mm 17 x 100 mm
Recommended Light Working Distance 50 - 300 mm 50 - 300 mm
Risk Class (according to IEC 62471) RG3 RG3
Basler Light Bar-17x100-UV-x
Conformity CE (includes RoHS), IP54, IP67
Certificates for your light model
For more information, see the Compliance section of the Basler website.

Radiant Intensity#

Radiant Intensity (W/sr)
Basler Light Bar-17x100-UV365 3.2
Basler Light Bar-17x100-UV395 2.56

Electrical Specifications#

Basler Light Bar-17x100-UV-x
Required Power for Voltage Control Mode
(17x100-UV-x)
24 VDC ± 5 % / 6 W
Required Current for Current Control Mode 540 mA
Recommended max. LED Current for Strobe Mode
(50 % Duty Cycle, < 500 ms Pulses)
900 mA
Recommended max. LED Current for Strobe Mode
(25 % Duty Cycle, < 50 ms Pulses)
1350 mA
Recommended max. LED Current for Strobe Mode
(10 % Duty Cycle, < 5 ms Pulses)
1800 mA

Mechanical Specifications#

Basler Light Bar-17x100-UV-x
Dimensions
(H x W x D)
27 x 110 x 23 mm
Weight 125 g
Material Anodized aluminum housing with PMMA light cover
Connector M12 5-pin male

Bar Light Dimensions#

Basler Light Bar-17x100-UV-x

Connector Pin Numbering#

Info

UV lights are equipped with an M12 5-pin connector. For more information about the installation, see here.

Info

The pin assignment of the light's connector differs depending on whether you want to use the internal or an external controller. For more information, see the respective tables in the Installation chapter.

Environmental Requirements#

Temperature During Operation 10–30 °C (50–86 °F) / 45 °C (113 °F)a
Humidity During Operation 30–70 %

  1. For steady light operation without additional heat dissipation measures, a maximum of 30 °C (86 °F) is recommended. For a maximum of 45 °C (113 °F), heat dissipation measures are mandatory.
    For flash light operation with a maximum 10 % duty cycle, a maximum of 45 °C (113 °F) is also permissible.