Basler Light Spot-13FWHM-x#

Basler Spotlights can be used to illuminate objects at long distances.

Basler Light Spot

Key Features#

  • Internal LED controller with 2 operating modes
  • Compatible with Basler SLP Strobe Controller
  • Preconfigured hardware components
  • Various sizes and LED colors

General Specifications#

Basler Light Spot-13FWHM-Red Basler Light Spot-13FWHM-White Basler Light Spot-13FWHM-Blue Basler Light Spot-13FWHM-Infrared
Order Number 2200000855 2200000751 2200000824 2200000886
Peak Wavelength 625 nm - 465 nm 850 nm
Color Temperature - 5000 K - -
LED Color Red White Blue Infrared
Beam Angle 13° 13° 13° 13°
Recommended Light Working Distance 100–700 mm 100–700 mm 100–700 mm 100–700 mm
Risk Class (according to IEC 62471) RG2 RG2 RG2 RG2
Basler Light Spot-13FWHM-x
Conformity CE (includes RoHS), FCC, IP54, UKCA
Certificates for your light model
For more information, see the Compliance section of the Basler website.

LED Specifications#

Spotlight Series 13FWHM-x
Luminous Power of
White LEDs (lumen)
818
Radiant Power of
Red LEDs (mW)
348
Radiant Power of
Blue LEDs (mW)
TBD
Radiant Power of
IR LEDs (mW)
2532

Electrical Specifications#

Spotlight Series 13FWHM-x
Required Power for Voltage Control Mode 24 VDC ± 10 %,
8 W
Required Current for Current Control Mode 600 mA
Recommended max. LED Current for Strobe Mode
(50 % Duty Cycle, 100 ms Pulses)
900 mA
Recommended max. LED Current for Strobe Mode
(25 % Duty Cycle, 20 ms Pulses)
1200 mA
Recommended max. LED Current for Strobe Mode
(10 % Duty Cycle, 5 ms Pulses)
1500 mA
Recommended min. Flash Time in Strobe Mode 100 µs

Mechanical Specifications#

Spotlight Series 13FWHM-x
Dimensions
(H x W x D)
56 x 46 x 46 mm
Weight 200 g
Material Anodized aluminum housing with PMMA light cover
Connector M8 socket, 4-pin male connector

Spotlight Dimensions#

Basler Spotlight 13FWHMx

Environmental Requirements#

Temperature During Operation 10–30 °C (50–86 °F) / 45 °C (113 °F)a
Humidity During Operation 30–70 %

  1. For steady light operation without additional heat dissipation measures, a maximum of 30 °C (86 °F) is recommended. For a maximum of 45 °C (113 °F), heat dissipation measures are mandatory.
    For flash light operation with a maximum 10 % duty cycle, a maximum of 45 °C (113 °F) is also permissible.

Performance Charts#

Peak Illuminance versus Light Working Distance (LWD)#

Peak Illuminance versus Light Working Distance (LWD)

Info

Diagram is based on the following reference model: BL Spot-13FWHM-White.

Spectrum#

Spectrum

Uniformity#

Uniformity

Info

The values in the graph above are measured in mm.

Uniformity Intensity