Driver Board 2x2#

Info
The Driver Board 2x2 is suitable for the following camera models:
- ace 2
- boost R
- racer 2 S
You can also use other Basler cameras. In that case, observe the circuit diagram shown below.
| Driver Board 2x2 | |
|---|---|
| Order Number | 2200002796 |
Key Features#
- Four driver channels with up to 240 W peak light power in total
- Convenient screw terminal connectors
- GPIO and opto-coupled input lines
Mechanical Specifications#
| Size (L x W x H) | 86 x 54 x 14 mm |
| Weight | 34 g |
Electrical Specifications#
Input Specifications#
| Function | Line | Status | Min. Voltage (VDC) | Max. Voltage (VDC) |
|---|---|---|---|---|
| Supply Voltage | - | - | 12a | 24 |
| Opto-Coupled I/O Input Line | Line 1 | Low High | 0 2.2 | 1.1 24 |
| General Purpose I/O (GPIO) Line | Line 2 | Low High | 0 2 | 0.8 24 |
| General Purpose I/O (GPIO) Line | Line 3 | Low High | 0 2 | 0.8 24 |
-
Minimum voltage may vary depending on connected components and load.
Circuit Diagram#
The following drawing shows the circuit diagram of the Driver Board 2x2.
Environmental Specifications#
| Operating Temperature | 0–55 °C (32–131 °F) |
| Storage Temperature | -20–70 °C (-4–158 °F) |
| Humidity | 20–80 % relative, non-condensing |
General Information#
| Conformity | CE (includes RoHS), UKCA, FCC, KC |
| Warranty | 3 years |
Use Cases#
Use Case 1 - Line Status Detection#
Check and detect various states of production lines or conveyor systems using the Driver Board 2x2 with dedicated line sensors.
Use Case 2 - Trigger System#
Use an external trigger source (e.g., light barrier, push button, or PLC) on Line 2 to start image acquisition with the Driver Board 2x2.
Use Case 3 - Simple Light#
Synchronize a light (e.g., 24 V LED panel without internal control) with the camera's exposure via Line 3.