Skip to content
STAGING SERVER
DEVELOPMENT SERVER

Basler Vision Connector: Troubleshooting#

This topic contains solutions for common problems when working with Basler Vision Connector.

The Camera Isn't Detected#

The Edge Device can detect the camera only when the camera's IP address is in the layer 2 network range. If the camera doesn't appear in the Basler Vision Connector, set the IP address on a computer that isn't the Edge Device. You can use the pylon IP Configurator.

For more information, see Configuring the Camera's IP Address.

An Error Occurs During the Installation of the Basler Vision Connector App#

You must enable the layer 2 network on the Industrial Edge Device before you install the Basler Vision Connector. If the layer 2 network is disabled, an error occurs during installation.

Enable the layer 2 network on the Industrial Edge Device under Settings > Connectivity > LAN Network.

For more information, see Enabling the Layer 2 Network on Your Edge Device.

The MQTT User Can't Access the Basler Vision Connector Topics#

The MQTT user that you configure in the Basler Vision Connector must have permission to access every MQTT topic of the connector. You set this user name and password during installation. The default MQTT root topic is BaslerVisionConnector.

Grant this user access to every topic of the Basler Vision Connector.

For more information, see MQTT in the Messaging Concept.

A Recipe Can't Be Opened in the Basler Vision Connector Web UI#

If a recipe can't be opened in the Web UI, it might be for one of the following reasons:

  • The recipe was created or edited in a pylon version higher than 26.10. Create or edit the recipe in pylon version 26.10 or lower. For more information, see Restrictions.
  • A vTool license required by the recipe is missing. Assign a Basler Vision Connector vTools license for every licensable vTool in the recipe. For more information, see Basler Vision Connector Licensing.
  • The pins of the recipe's input terminal are incorrect, for example because a pin is named incorrectly. Name the pins according to the naming rules. For more information, see Naming of Input Pins.

On VMware ESXi, the Camera Isn't Detected#

If you have installed a Siemens Virtual Edge Device on a VMware ESXi virtual machine, and your camera isn't detected, change the Distributed Port Group settings on VMWare ESXi. In the Distributed Port Group - Edit Settings dialog, set all settings to Accept:

Distributed Port Group Settings on VMware ESXi

For further information about the Port Group Settings, refer to the VMware Documentation

Maximum Transmission Unit (MTU) on VMware ESXi#

MTU optimization settings configured during the installation of the Basler Vision Connector aren't stored on VMware ESXi virtual machines. You can change the MTU settings on your VMware ESXi virtual machine as described in the VMware Documentation.